دانلود مقاله 3درD electrical model of a neuroprosthesis stimulator based on the concept of stimulus

جمعه 29 بهمن 1395
3:28
علی

برای دریافت اینجا کلیک کنید

دانلود مقاله 3درD electrical model of a neuroprosthesis stimulator based on the concept of stimulus router system تحت word دارای 4 صفحه می باشد و دارای تنظیمات در microsoft word می باشد و آماده پرینت یا چاپ است

فایل ورد دانلود مقاله 3درD electrical model of a neuroprosthesis stimulator based on the concept of stimulus router system تحت word کاملا فرمت بندی و تنظیم شده در استاندارد دانشگاه و مراکز دولتی می باشد.

این پروژه توسط مرکز مرکز پروژه های دانشجویی آماده و تنظیم شده است

توجه : در صورت  مشاهده  بهم ريختگي احتمالي در متون زير ،دليل ان کپي کردن اين مطالب از داخل فایل ورد مي باشد و در فايل اصلي دانلود مقاله 3درD electrical model of a neuroprosthesis stimulator based on the concept of stimulus router system تحت word ،به هيچ وجه بهم ريختگي وجود ندارد


بخشی از متن دانلود مقاله 3درD electrical model of a neuroprosthesis stimulator based on the concept of stimulus router system تحت word :

سال انتشار: 1392
محل انتشار: بیستمین کنفرانس مهندسی زیست پزشکی ایران
تعداد صفحات: 4
چکیده:

Lost sensory or motor functions can be restored using electrical neural prostheses (NP), which include surface NPs, implanted or subcutaneous NPs and the more recentStimulus Router System (SRS). The latter type of NP outperforms the other types in its selective excitation and least invasiveness.In each case, the achieved performance depends on a multitude of design factors among which the electrical excitation waveformshape, frequency, duration of pulses, configuration of electrodes,number of intervals, thermal conditions and electrode material. To investigate the effects of these parameters on the distributionof electric current inside biological tissues, numerical modeling can be employed as a powerful computational method. Inthis work, a 3-D electrical model is proposed to simulate the distribution of electric potentials and currents in the adulthuman forearm for an SRS NP. At the frequency of 50Hzand for a 5mA square waveform current source, results of our simulation show that the ratio of the current flowing insidethe implanted conductor to the current applied to the cathodal electrode (capture ratio) is approximately equal to 2:02%. Thisvalue is close to the experimentally reported result for the SRS, 1:9%, giving an absolute error of 0:12% and relative error of 6:3%.


برای دریافت اینجا کلیک کنید

[ بازدید : 4 ] [ امتیاز : 4 ] [ امتیاز شما : ]
تمامی حقوق این وب سایت متعلق به دانلود مقالات است. | قدرت گرفته از Blogroz.ir| طراح قالب Blogroz.ir
× بستن تبلیغات